Library fails to operate and error code: Mechanical Block Code: 8A 0E, is seen on library GUI and Operator panel Display.

Mechanical Block Code: 8A 0E

As per error code: 8A refers to Slider obstructed and 0E: Error refers to slider init, get range failed, where Slider is the part of the robotics assembly that plunges in and out for get and put operations.

==================================
0001 19.11.15 15:14:04.30 Libctrl task Error - HE: slider blocked
Return status: 0x80 - command failed
Global error code: 0x8A - HE: slider blocked
Robotic movement error: 0x0E - error during slider init -> get range
Task originator: 0x00 - Libctrl task
Extender library specifier: 0x00 - master library
0002 19.11.15 15:09:03.21 Libctrl task Error - HE: slider blocked
Return status: 0x80 - command failed
Global error code: 0x8A - HE: slider blocked
Robotic movement error: 0x0E - error during slider init -> get range
Task originator: 0x00 - Libctrl task
Extender library specifier: 0x00 - master library
0003 19.11.14 14:39:19.34 Libctrl task Error - HE: slider blocked
Return status: 0x80 - command failed
Global error code: 0x8A - HE: slider blocked
Robotic movement error: 0x0E - error during slider init -> get range
Task originator: 0x00 - Libctrl task
Extender library specifier: 0x00 - master library
0004 19.11.13 17:16:52.85 Libctrl task Error - HE: slider blocked
Return status: 0x80 - command failed
Global error code: 0x8A - HE: slider blocked
Robotic movement error: 0x0E - error during slider init -> get range
Current command: 0x15 - move cartridge
Task originator: 0x02 - CDB interpreter task
Extender library specifier: 0x00 - master library
Source element type.: 0x02 - storage slot
Element number: 0x02, 2
Destination element type.: 0x04 - tape drive
Element number: 0x01, 1
Component ID type: 0x02 - medium PVT (barcode)
Component ID: 000002L4
0005 19.11.13 17:15:35.87 Libctrl task Error - HE: cannot find slider block
Return status: 0x80 - command failed
Global error code: 0x8F - HE: cannot find slider block
Robotic detailed info: 0x40, 64
Current command: 0x15 - move cartridge
Task originator: 0x02 - CDB interpreter task
Extender library specifier: 0x00 - master library
Source element type.: 0x04 - tape drive
Element number: 0x01, 1
Destination element type.: 0x02 - storage slot
Element number: 0x0F, 15
Component ID type: 0x02 - medium PVT (barcode)
Component ID: 000015L4