SD-WAN Edge Interface Error
(Doc ID 2645266.1)
Last updated on DECEMBER 02, 2021
Applies to:
Oracle Talari E100 - Version APN 7.3 and laterTalari
Symptoms
Issue Clarification
------------------------------------------------------------
1. SD-WAN Edge device interface auto-negotiating to half-duplex
2. Zero link light activity with the SD-WAN Edge interface properly configured
Issue Clarification:
------------------------------------------------------------
1. Physical cabling: tested and validated for proper connections to the SD-WAN Edge device and infrastructure devices
2. SD-WAN Edge configuration: at the web interface, navigated to Configuration > Local Network Settings, some interfaces not set to auto-negotiate as well as displaying half-duplex
2. LAN switch review: switch configuration we observed interface connections to the SD-WAN Edge device with some interfaces statically set duplex/speed and some interfaces as auto for duplex/speed
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |