Symptoms

T10000 Drive goes into maintenance mode even after drive reboots.
Drive does not allow any new load of tapes.
Tape stuck in drive unable to eject the tape.

FSC: 5803 SRV_FSC_TAPE_LEADER_UNBUCKLE_FAILURE
MIM Code: INOPERABLE

FRU: HARDWARE CONF: 50%
FRU: MEDIA CONF: 50%

Summary: |BUCKLER |TAPE | *** |

Field Text:
Tape Leaders failed to unbuckle during an unload operation.
Manual intervention is required.
Eject the tape that failed and verify if the leader is in the correct location.
 

       AND

FSC: 5916 REEL_FSC_LEADER_NOT_HOME
MIM Code: DEGRADED

FRU: MEDIA       CONF: 50%
FRU: HARDWARE   CONF: 40%
FRU: MICROCODE   CONF: 10%

Summary: |TAPE            |REEL SYSTEM     |SERVO CODE      |

Field Text:
Machine reel 'global' position indicates the cartridge leader has not returned all the way into the cartridge during unload attempt.

 