My Oracle Support Banner

Support Strategy for Replacing an Aura 6 Flash card with an Aura 8 Flash card (Doc ID 2673810.1)

Last updated on FEBRUARY 16, 2023

Applies to:

Oracle SuperCluster M6-32 Hardware - Version All Versions and later
Fujitsu M10-4S - Version All Versions and later
Fujitsu M10 PCI Expansion Unit - Version All Versions and later
Exadata X6-2 for Bare Metal - Version All Versions and later
Fujitsu SPARC M12-1 - Version All Versions and later
Information in this document applies to any platform.

Goal

 BEFORE CONTINUING with the order for a replacement of an Aura 6 F320 NVMe Flash Card, please ENSURE you have READ and UNDERSTAND the information contained in this document.

Failure to ADHERE to this document WILL result in delays to Customer problem resolution.

 

IMPORTANT NOTE: The Aura 6 Flash Accelerator F320 NVMe (Samsung MZPLK3T2HCJL-000U3 - Part numbers 7317693) has very LIMITED AVAILABILITY. Replacement per system is as follows.

 

Updating your software to the recommended version code will help to expedite part replacements. See Table below for recommended software versions needed.

 

Product Min Support SW Old part number Alternate part number
Bare Metal Cloud Service Exadata X6-2 Storage Cell (X6-2L) * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
Exadata Cloud Machine X6-2 * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
M10-1 No minimum SW requirement.  7317693 7359992
M10-4 No minimum SW requirement.  7317693 7359992
M10-4S No minimum SW requirement.  7317693 7359992
M10/M12 PCI Expansion Unit No minimum SW requirement.  7317693 7359992
Netra SPARC S7-2 N/A 7317693 Use Aura 6. Cannot use the Aura 8
OCI Exadata X6-2 Compute Rack Storage Cell (X6-2L) * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
Oracle Exadata Storage Expansion Rack X6-2 (X6-2L) * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
Oracle Exadata X6-2 * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
Oracle Exadata X6-8 Storage Cell (X6-2L) * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
Oracle Exalytics In-Memory Machine X6-4 N/A  7317693 Use Aura 6. Cannot use the Aura 8
Oracle Server X5-4 System SW3.1.4 7317693 7361454
Oracle Server X5-8 System SW3.1.4 7317693 7361454
Oracle Server X6-2L System SW 2.4.2 / ILOM 4.0.4.47 7317693 7361454
Oracle SuperCluster M6-32 Storage Server (X6-2L) * Q4,2019 QSFDP using SW19.2.7.0.0 *** 7317693 7361454
Oracle SuperCluster M7 Storage Server (X6-2L) * Q4,2019 QSFDP using SW19.2.7.0.0 *** 7317693 7361454
Oracle SuperCluster T5-8 Storage Server (X6-2L) * Q4,2019 QSFDP using SW19.2.7.0.0 *** 7317693 7361454
PDIT Exadata X6-2 Storagecell (X6-2L) * Exadata Storage Server SW19.2.2.0.0 7317693 7361454
SPARC M12-1 No minimum SW requirement.  7317693 7359992
SPARC M12-2 No minimum SW requirement.  7317693 7359992
SPARC M12-2S No minimum SW requirement.  7317693 7359992
SPARC M7-16 ** N/A 7317693 Use Aura 6. Cannot use the Aura 8 at this time.
SPARC M7-8 ** N/A 7317693 Use Aura 6. Cannot use the Aura 8 at this time.
SPARC S7-2 Server  S11.4, HMP v2.4.4.0 7317693 7361454
SPARC S7-2L Server  S11.4, HMP v2.4.4.0 7317693 7361454
SPARC T7-1  S11.4, HMP v2.4.4.0 7317693 7361454
SPARC T7-2  S11.4, HMP v2.4.4.0 7317693 7361454
SPARC T7-4  S11.4, HMP v2.4.4.0 7317693 7361454
Zero Data Loss Recovery Appliance X6 Storage Cell (X6-2L) * Exadata Storage Server SW19.2.2.0.0 7317693 7361454

 

IMPORTANT NOTES:

   * In Exadata Storage Cell (X6-2L) servers, replacing an Aura6 card with an Aura8 card is a one way sub. Once the F320 is replaced with an F640v2, there cannot be any subsequent replacements of that F640v2 with an F320, an F640v2 Flash Card must remain an F640v2. The software image won't allow going backwards and will not function correctly if you try to swap a F640v2 with a F320. Systems that this applies to are indicated with an *.

   ** In Sparc M7-8 and M7-16 systems, additional configuration documentation required to support the F640 v2 alternate card is currently not available.

   *** Oracle SuperCluster M Series - Q4,2019 QSFD has both 19.2.7.0.0 and 18.1.21.0.0 versions for the Exadata Storage Cells and the new card will not work on 18.x versions It is only supported on 19.2.7.0.0 or later versions.

Solution

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Goal
Solution
References

My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.