Symptoms

Customer added new four IBM LTO8 FC drives into SL3000 Library.

Drive communication problems and frequently drives going into Inoperative Status - Problems started only with newly installed IBM LTO8 Drives.

At the same time, Old IBM LTO6 drives are working fine in Library without any issues.

 

10WT018221


FSC(1320): Drive communication time-out 1,1,1,1,2            <<-----------
Device SN: 57100xxxxxxx
Device Model: SL3000
Event information: Can not switch library to drive because drive is no in the configuration
3-23619063523

FSC(1107): Drive not unloaded for fetch - on rewindUnload         <<-----------
Device SN: 57100xxxxxxx
Device Model: SL3000
Event information: Can not switch library to drive because drive is no in the configuration
SuspectDeviceAddress = 1.1.1.1.2

 

HW Address: 1.1.3.1.2
Total EWI Count for 1.1.3.1.2: 47
Error Reason(s):
Warning Reason(s):  deviceDB_inoperative    <<-----------
Drive Serial: 10WT015462
Drive Type: IbmUltrium8
Drive Tray Serial: 016xxxx+202xxxxxxx
Bay: Drive_Bay6
HLI Address: X.0.12.6

Changes

Customer added four new IBM LTO8 FC drives into SL3000 Library.

Cause