My Oracle Support Banner

T10000D - Drive Getting FSC 3944 RO_FSC_WRT_FIELD_ERROR (Doc ID 2768771.1)

Last updated on APRIL 19, 2021

Applies to:

Sun StorageTek SL3000 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms


1.1.2.1.4     15   5790040xxxxx  464970G+1806Lxxxxx  T10000d-Enc         StorageTek     empty               4.16.101-5.60  ok             LOD-54    N/A

HW Address: 1.1.2.1.4
Total EWI Count for 1.1.2.1.4: 20
Error Reason(s):
Warning Reason(s):  1303 1320 3955 3955_604
Drive Serial: 5790040xxxxx
Drive Type: T10000d-Enc
Drive Tray Serial: 464970G+1806Lxxxxx
Bay: Drive_Bay15
HLI Address: X.0.12.13
Vendor: StorageTek
Partition ID: N/A
EWI Messages:

Drive_Bay15(1.1.2.1.4)

1303 - (1X)
Failure from drive Code: 601 - Drive is loaded, drive 1,1,2,1,4: rewindUnload FAILED with unitCheck 3944 - drive is loaded (, driveType = T10000d-Enc, driveFirmware = 4.16.101-5.60)1</cartridgeLife
VOLSERS seen in 1303 messages: A01214T2 (x1)
(Errors Started - 2021-03-26 11:46:01 Errors Stopped - 2021-03-26 11:46:01)
1320 - (1X)
Drive communication time-out 1,1,2,1,4
(Errors Started - 2021-03-26 12:46:25 Errors Stopped - 2021-03-26 12:46:25)
3204 - (1X)
System error - Invalid state transition, state=Error transtion=Vary offline
(Errors Started - 2021-03-26 12:53:36 Errors Stopped - 2021-03-26 12:53:36)
3287 - (1X)
Device transitioned to not ready, address=(Drive_Bay15)1,1,2,1,4
(Errors Started - 2021-03-26 12:57:57 Errors Stopped - 2021-03-26 12:57:57)
3955 - (3X)
Error from device Code: 601 - Drive is loaded, drive 1,1,2,1,4: rewindUnload FAILED with unitCheck 3944 - drive is loaded (, driveType = T10000d-Enc, driveFirmware = 4.16.101-5.60)
Error from device Code: 604 - Drive is not functional, drive 1,1,2,1,4: getState FAILED, resultCode = 6406
VOLSERS seen in 3955 messages: A01214T2 (x1)
(Errors Started - 2021-03-26 11:46:01 Errors Stopped - 2021-03-26 12:53:28)
3992 - (12X)
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with unitCheck 6142 ()
Warning from device, drive 1,1,2,1,4: load Successful with mediaError: , fsc:  FSC: 5135 (sn = 579004008006)
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with mediaError: ,  FSC: 5135
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with unitCheck 395B ()
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with mediaError: ,  FSC: 395E
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with unitCheck 377A ()
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with mediaError: ,  FSC: 0000
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with mediaError: ,  FSC: 3961
Warning from device, drive 1,1,2,1,4: rewindUnload Successful with mediaError: ,  FSC: 3944

VOLSERS seen in 3992 messages: A00012T2 (x1) A00398T2 (x1) A01034T2 (x1) A01214T2 (x1) CE0413T2 (x1) CE1211T2 (x2) CE1241T2 (x1) CE1381T2 (x1) CE1432T2 (x1) CR0413T2 (x1) CR0422T2 (x1)
(Errors Started - 2021-03-21 16:20:57 Errors Stopped - 2021-03-26 11:56:15)

FSC Encountered: 3961
Date:  2021-03-25 08:36:36
Drive: 1.1.2.1.4  Volsers: CE1432T2 ( 1X )  

(FSC Exact Match Found)
FSC: 3961 RO_FSC_PW_LIMIT_ERROR_DUE_TO_WITH_VR2_DATA
MIM Code: NONE

1.1.2.1.4 - Volumes: CE1211T2 , A00012T2 , A01034T2 , CR0422T2 , CE1432T2 , A01214T2 , CE1381T2
Last message seen: 2021-03-26 11:56:15