SL150 FSC 9170 TAPE_SLOT_OBSTRUCTION
(Doc ID 2836168.1)
Last updated on JUNE 05, 2024
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions to All Versions [Release All Releases]Information in this document applies to any platform.
Symptoms
Continuous tape slot obstruction error 9170 happening in Module 8 Right Magazine. A reboot clears the error temporarily, but within a few minutes error returns.
TAPE_SLOT_OBSTRUCTION - Fault Code:9170 <<--------------
Probable Failed Components
1. Module 8 Right Magazine
2. Robot
Actions to Take
Check and clear obstruction encountered in last accessed slot. <<--------------
Replace Robot or Magazine if no obstruction readily detected.
------------------
O,3825,2022-01-18T07:53:05.035,9170,TAPE_SLOT_OBSTRUCTION,1,Module 8 Right Magazine,2,Robot,,,,,,,Check and clear obstruction encountered in last accessed slot.
2022-01-18T07:53:03.573, 9.3.1, 510, robot, /usr/local/bin/Ifm, error, 0000, 5134, "Director - putResponse() srv_coord_put: hit something during reach extend. Might have hit the front of the cell or the cell may be occupied.; End of Text"
152.FruStatusReason="Reach put move blocked. Possible cartridge in cell or cartridge contacted cell or drive."
152.FruStatusReasonCode=5134
-----------------------
2022-01-12T18:34:44.152, 9.3.1, 510, robot, /usr/local/bin/Ifm, error, 0000, 5134, "Director - putResponse() srv_coord_put: hit something during reach extend. Might have hit the front of the cell or the cell may be occupied.; End of Text"
2022-01-12T18:34:59.376, 0.0.0, 3200, ifm, , error, 3000, 3313, "(request id = HOST/0x914cc30) IfmMove::commonMoveCommand(): PUT request of tape P12310L7 from (P:MSRC) 0:1,R,1,5 to (P:MSRC) 0:9,L,3,1 failed:"