ZFS Storage Appliance: Riser Faulty After DIMM Replacement SENSOR-8000-97
(Doc ID 2860121.1)
Last updated on APRIL 04, 2022
Applies to:
Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]Sun ZFS Storage 7120 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-4 - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.
Symptoms
Memory Riser PX/MRX appeared faulty
Suspect 1 of 1 :
Problem class : fault.memory.intel.memory-riser.indicator-set
Certainty : 100%
FRU
Status : faulty
Location : "/SYS/Px/MRx"
Manufacturer : unknown
Name : unknown
Part_Number : unknown
Revision : unknown
Serial_Number : unknown
Chassis
Manufacturer : Oracle Corporation
Name : SUN FIRE X4470 M2 SERVER
Part_Number : Not applicable
Serial_Number : xxxxxxxx
Resource
Status : faulty
Description : A sensor indicates that the memory riser card 'PX/MRX' has been
diagnosed as faulty by the Service Processor.
Response : None.
Impact : The system may have been reset.
Action : Please refer to the associated reference document at
http://support.oracle.com/msg/SENSOR-8000-97 for the latest
service procedures and policies regarding this diagnosis.
Changes
Earlier, PX/MRX DIMM X was replaced.