ESSBASE: Unloading Applications Errors "ERROR - 1042017 - Network Error: Timed Out Before Receiving All Data" and "GLIBC Detected Invalid Pointer"
(Doc ID 2084839.1)
Last updated on MARCH 15, 2024
Applies to:
Hyperion Essbase - Version 11.1.2.3.000 and laterLinux x86-64
Symptoms
During nightly Essbase process that unloads an application, the following error is logged in the application log, though the application appears to unload successfully:
MAXL> alter system unload application {appname};
ERROR - 1042017 - Network error: Timed out before receiving all data.
ERROR - 1042017 - Network error: Timed out before receiving all data.
The Essbase.log has the following error:
*** glibc detected *** /Oracle/Middleware/EPMSystem11R1/products/Essbase/EssbaseServer/bin/ESSSVR: free(): invalid pointer: 0x000000000b0e5e20 ***
======= Backtrace: =========
Sun Jul 5 01:02:47 2015 Local ESSBASE0 140562145617664 Info (1054005) Shutting down application {appname}
Changes
Error occurs post upgrade from 11.1.2.1 to 11.1.2.3. In earlier version 11.1.2.1, there was no issue unloading applications.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |