OBIA 7964: DAC Server Hung And Throwing Error: "ANOMALY INFO::: The server is unable to bind to the specified port: 3141" (Doc ID 2345379.1)

Last updated on MAY 16, 2023

Applies to:

Business Intelligence Applications Consumer - Version 7.9.6.4 and later
Information in this document applies to any platform.

Symptoms

On Oracle Business Intelligence Applications Consumer 7.9.6.4 version, 

Error:

ANOMALY INFO::: The server is unable to bind to the specified port: 3141Please update repository with a valid Server Port number
MESSAGE:::Connection refused: connect
EXCEPTION CLASS::: java.net.ConnectException

java.net.PlainSocketImpl.socketConnect(Native Method)
java.net.PlainSocketImpl.doConnect(Unknown Source)
java.net.PlainSocketImpl.connectToAddress(Unknown Source)
java.net.PlainSocketImpl.connect(Unknown Source)
java.net.SocksSocketImpl.connect(Unknown Source)
java.net.Socket.connect(Unknown Source)
java.net.Socket.connect(Unknown Source)
java.net.Socket.<init>(Unknown Source)
java.net.Socket.<init>(Unknown Source)
com.siebel.etl.net.QServer.bind(QServer.java:295)
com.siebel.etl.net.QServer.<init>(QServer.java:189)
com.siebel.etl.net.QServer.main(QServer.java:499)
ANOMALY INFO::: The server is unable to bind to the specified port: 3141 Please update repository with a valid Server Port number
Shutting down server...
MESSAGE:::Unrecognized Windows Sockets error: 0: JVM_Bind
EXCEPTION CLASS::: java.net.SocketException

Environment Details:

  1. OBIA Version: 7.9.6.4
  2. DAC version: 11.1.1.6.4.20121119.2022

Note: 3141 here is the default DAC Port.

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution
 Approach 1: Change Port Number
 Approach 2: Kill the existing process


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.