OBIA 7964: DAC Server Hung And Throwing Error: "ANOMALY INFO::: The server is unable to bind to the specified port: 3141"
(Doc ID 2345379.1)
Last updated on MAY 16, 2023
Applies to:
Business Intelligence Applications Consumer - Version 7.9.6.4 and laterInformation in this document applies to any platform.
Symptoms
On Oracle Business Intelligence Applications Consumer 7.9.6.4 version,
- DAC Server hung intermittently and cannot restart the execution plan. Due to hung, DAC Client is not getting connected to DAC server.
- The following error messages can be found in DAC Server Log -
Error:
ANOMALY INFO::: The server is unable to bind to the specified port: 3141Please update repository with a valid Server Port number
MESSAGE:::Connection refused: connect
EXCEPTION CLASS::: java.net.ConnectException
java.net.PlainSocketImpl.socketConnect(Native Method)
java.net.PlainSocketImpl.doConnect(Unknown Source)
java.net.PlainSocketImpl.connectToAddress(Unknown Source)
java.net.PlainSocketImpl.connect(Unknown Source)
java.net.SocksSocketImpl.connect(Unknown Source)
java.net.Socket.connect(Unknown Source)
java.net.Socket.connect(Unknown Source)
java.net.Socket.<init>(Unknown Source)
java.net.Socket.<init>(Unknown Source)
com.siebel.etl.net.QServer.bind(QServer.java:295)
com.siebel.etl.net.QServer.<init>(QServer.java:189)
com.siebel.etl.net.QServer.main(QServer.java:499)
ANOMALY INFO::: The server is unable to bind to the specified port: 3141 Please update repository with a valid Server Port number
Shutting down server...
MESSAGE:::Unrecognized Windows Sockets error: 0: JVM_Bind
EXCEPTION CLASS::: java.net.SocketException
Environment Details:
- OBIA Version: 7.9.6.4
- DAC version: 11.1.1.6.4.20121119.2022
Note: 3141 here is the default DAC Port.
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
Approach 1: Change Port Number |
Approach 2: Kill the existing process |