E1: 41: Item Reclassifications (P4116 W4116B) Lot Grade (LOTG) Field not Validated Against UDC 40|LG
(Doc ID 2538725.1)
Last updated on FEBRUARY 26, 2024
Applies to:
JD Edwards EnterpriseOne Inventory Foundation - Version 9.1 and laterInformation in this document applies to any platform.
Symptoms
In P4116 application, on the W4116B form, the Lot Grade (LOTG) field can be edited/modified in the Grid but there is no validation done against UDC 40|LG, while DD item LOTG has UDC 40|LG as Edit Rule.
No error message is received if a value not defined in UDC 40|LG is entered
Steps:
1. P4116 enter new reclassification
2. Enter the From and To item and lots
The TO lot is a new lot.
3. On the TO line, change the Lot Grade to something that does was not defined in the UDC 40|LG
4. No error message even though FDG is not in the UDC
Note: If you open the new lot in P4108, the error message is displayed
Desired Outcome:
Error message should be displayed if LOTG receives a value not defined in UDC 40|LG. The system should validate the value against the UDC
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |