My Oracle Support Banner

E1: OMW: P98220W UDO Promotion Fail with Error 10632 'Error changing status for project' When UDO is Moved to Project Typed in Lowercase in SQL Database (Doc ID 2739381.1)

Last updated on APRIL 16, 2024

Applies to:

JD Edwards EnterpriseOne Tools - Version 9.2 and later
Information in this document applies to any platform.

Symptoms

Pre-Requisite: Database platform must be SQL.

UDO is moved from default project to another project typed in lowercase.

When UDO is promoted from DV to PY, it fails with OMW Logging Error 10632 '153Y Object not changed by project'.

Steps to reproduce:

1. P98230 click Constants
    Enter the initial project status for all new projects= 21
    Enter the User Role to use when assigning the originator to a project= 02

2. P0013 add Grid Format P0013GFA

3. P0018 add Grid Format P0018GFA

4. P98220U P0013GFA, P0018GFA are at 02 Editing status in Default Project

5. P98220W
    Add OMW project PRJ08 (typed in uppercase)
    Check box 'Default Project'
    P0013GFA Row Action 'Move Objects to Project', PRJ08 (typed in uppercase)
    P0018GFA Row Action 'Move Objects to Project', prj08 (typed in lowercase)

6. P98220U
    P0013GFA at 02 Editing status in OMW Project PRJ08, row-exit(Approve/Share)
    P0018GFA at 02 Editing status in OMW Project prj08, row-exit(Approve/Share)

7. P98220W
    Advance Project PRJ08 to status 26, 'Error changing status for project'
    Error detail displayed for "Error changing status for project"
    ER Details:
    Form: P98220W_W98220WAC
    Control Id: 103
    Control Title: Advance Project Action
    Event: Button clicked
    Line No: 76
    Error ID: 10632

8. PRJ08 row-exit(Logging)

9. PRJ08 Action 38 Status Change FromStatus=21 ToStatus=26
    Row-exit(Log Detail)

10. P0013GFA (moved to project PRJ08) promote successfully because UDO F9861W.SIMODCMT has PRJ08 in lowercase
      Log Sequence 2 131N Object Ready to be transferred/deleted
      Row-exit(Full Text)
      The following object is ready to be transferred (or deleted):
      Object: GF0013A_2012150011CUST
      Type: FORMAT
      Release: E920
     
     Log Sequence 3 145K Action call for Object returned Success
     Row-exit(Full Text)
     Success - Action: Transfer called for:
       Project: PRJ08
       Object: GF0013A_2012150011CUST
       Type: FORMAT
     by User: EONE returned success

11. P0018GFA moved to project prj08 (in lowercase) fail to promote because F9861W.SIMODCMT has prj08 in lowercase
      Log Sequence 4 131N Object Ready to be transferred/deleted
      The following object is ready to be transferred (or deleted):
      Object: GF0018A_2012150012CUST
      Type: FORMAT
      Release: E920

      Log Sequence 5 153Y Object not changed by project
      Row-exit(Full Text)
      Object GF0018A_2012150012CUST was not modified by this project and will not be transferred 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Cause
Solution
References


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.