E1: 46: Error 018A - Not Found in User Defined Code When Adding Replenishment Instructions in P46095
(Doc ID 2904401.1)
Last updated on OCTOBER 21, 2022
Applies to:
JD Edwards EnterpriseOne Warehouse Management - Version 9.1 and laterInformation in this document applies to any platform.
Symptoms
When adding Replenishment movement instructions in P46095 and populating the replenishment zone with a value from UDC 46/ZN it does not recognize the value and issues the error 018A - not found in User Defined Code (see error details below).
The value for replenishment zone had previously been added to UDC 46/ZN and the cache had been cleared.
not found in User Defined Code
An error has occurred in the grid on a hidden column (that is, a column that you cannot view). Please contact your system administrator.
not found in Use Defined Code 46 ZN
Error Details:
Form P46095_W46095E
Control Id 1
Control Title Grid (Putaway Zone)
Error ID 018A
Steps to Duplicate:
1) Set up new value in UDC 46/ZN
2) P46095 set up new movement instructions using the UDC value
3) Drop of line and receive error