E1: 31B: Error ID 126WIM - 'Invalid Move Volume' is Triggered When Using Additive Workbench - P31B84 Application to Create an ADDT Operation Set Between Two MOVTTV Operations
(Doc ID 3049011.1)
Last updated on SEPTEMBER 20, 2024
Applies to:
JD Edwards EnterpriseOne Blend Management - Version 9.2 and laterInformation in this document applies to any platform.
Symptoms
When using P31B84 - Additive Workbench application to create an ADDT operation that is set between two Tank to Tank Move operations (MOVTTV), the ADDT operation is created incorrectly, even if the system triggers a hard error correctly in P31B84.
The issue can be reproduced at will with the following steps:
- P31B94 > P31B69 – Create first MOVTTV operation to move some volume from tank # 1 to tank # 2; for this test move 200 GA.
- P31B87 – In the 'From Vessel' section set tank # 1, Instructed Move Quantity = 200 GA and in the 'To Vessel' section set tank # 2, with Before Lot Quantity = 1800.0000 GA. Hit on Calculate Move button. In the 'To' section, the After Planned Volume = 2000.0000 GA.
- P31B94 > P31B69 – Create the second MOVTTV operation to move some volume from tank # 2 to tank # 3; move 2000 GA.
- P31B87 – In the 'From Vessel' section set tank # 2, Instructed Move Quantity = 2000 GA and in the 'To Vessel' section set tank # 3, which is empty. Hit on Calculate Move button. In the 'To' section, the After Planned Volume = 2000.0000 GA.
- P31B94 - Select the MOVTTV op # 1 and take Edit Operation button. Edit the first MOVTTV operation and change the volume moved to be less than what was being moved in the 2nd MOVTTV operation. This will force a hard error on the 2nd MOVTTV operation.
- P31B69 – The Operation Header shows the details of the operation. Hit Continue button.
- P31B87 – In the 'From Vessel' section, for tank # 1, set the Instructed Move Quantity to 190 GA, instead of 200 GA and then hit Calculate Move button. In the 'To' section, the After Planned Volume = 1990.0000 GA, which is less than the quantity of 2000 GA moved on the second MOVTTV op. Save the operation details.
- P31B94 – Do a Find to refresh the data and notice the 2nd MOVTTV operation has the Operation Number field highlighted in red. In a real-life environment, this happens quite often, as the business users create operations 1-2 weeks into the future and then adjust volumes.
- P31B84 - Create an ADDT operations for the TO tank of the 1st MOVTTV (tank # 2) operation using Additive Workbench application. Use a start date that is between the Start Dates of the previous 2 MOVTTV operations, to have the ADDT operation Start Date created prior to the operation highlighted in red. In the 'Add Additive' form enter at least 2 additive items. Click on Calculate button.
- P31B84 – In the 'Vessel / Additive Quantity' section, the system fills in the Lot/Location details for each additive item and the corresponding Additive Quantity. Click on Create Operation button.
- P31B84 – In the 'Operation / WO Template Selection' section fill in the operation details (Winery, Operation / WO Description and Configured Operation Code). Hit Save and Close button.
- P31B84 – Receive error ID 126WIM – ‘Invalid Move Volume’, which is correct because the move volume is greater than the before lot quantity.
error ID 126WIM - 'Invalid Move Volume Warning':
A form level error has occurred.
CAUSE: The move volume is greater than the before lot quantity.
RESOLUTION: Move a volume that is less than or equal to the before lot quantity.
ER Details:
Form P31B84_W31B84C
Control Id 47
Control Title Set Operation
Event Button clicked
Line No 234
BSFN Details:
Source File b31b1190.c
Source Line 2984
Error ID 126WIM
Error 2 Warning
ER Details:
Form P31B84_W31B84C
Control Id 47
Control Title Set Operation
Event Button clicked
Line No 234
BSFN Details:
Source File n31b8041.c
Source Line 384
Error ID 0
BSFN DSTR Item 3
Hit the Cancel button. - P31B84 – In the 'Manage Additive' section hit Close button to cancel the creation of the additive operation.
- P31B94 – Check the list of operations and see that the ADDT operation was in fact created and the Actual Start Date of the ADDT operation is between the 2 MOVTTV operations. This is incorrect.
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |