W3P3.EXE Crash After Installation of 10g WebGate for IIS 7.5
(Doc ID 1507521.1)
Last updated on OCTOBER 09, 2023
Applies to:
Oracle Access Manager - Version 11.1.1.5.0 to 11.1.2.0.0 [Release 11g]Information in this document applies to any platform.
Symptoms
1) The WebGate installer informs the user "WebGate Server Configuration has been modified for WebGate
"Please restart your WebServer to complete the installation of WebGate"
2) After installation of the base code for the WebGate, the installation should be confirmed.
The confirmation is documented here
Here the guide indicates that the diagnostic URL should be used, which would exercise the webgate.dll
If the Webgate has been installed with the base installer AND patched without having had the installation verified ( by exercising the webgate.dll )
a crash of W3WP.EXE is observed.
W3WP.EXE IS CRASHING
Faulting application name: w3wp.exe, version: 7.5.7600.16385, time stamp: 0x4a5bd0eb
Faulting module name: MSVCR80.dll, version: 8.0.50727.4927, time stamp: 0x4a27427d
Exception code: 0xc000000d
The WebGate does not initialize, and not oblog (WebGate diagnostic log) is written.
Changes
Installation of base package has been completed and patch has been applied.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |