Definition Of a Serializer Where Its Factory Class Returns an Object Will Fail in Coherence 12.1.3 Onwards (Doc ID 1934433.1)

Last updated on FEBRUARY 24, 2017

Applies to:

Oracle Coherence - Version 12.1.3.0.0 and later
Information in this document applies to any platform.

Symptoms

Definition of a serializer by an <instance> element with a <factory-class-name>, where the factory class's getSerializer() method returns an Object instead of a Serializer, succeeds in Coherence versions up to and including 12.1.2, but fails in 12.1.3, so that a cluster node with such a cache configuration fails to start.

The serializer factory class looks like this:

 

Cause