Symptoms

Issue with file adapter polling

[2018-03-07T11:03:16.390+05:30] [soa_server1] [NOTIFICATION] [] [oracle.soa.adapter.file.inbound] [tid: DaemonWorkThread: '7' of WorkManager: 'default_Adapters'] [userId: weblogic] [ecid: 4a398510-b9ce-4ac5-b40b-5027f9a8662f-0000051d,0:1:22] [APP: soa-infra] [partition-name: DOMAIN] [tenant-name: GLOBAL] [composite_name: AS_BPEL_Outbound] [composite_version: 1.0] [service_name: AS_FileAdapter] Recovery still not possible after 240 attempts due to BINDING.JCA-11001[[
Invalid Input Directory.
Invalid Input Directory.
The value specified for the input (Physical/Logical)Directory activation parameter has an invalid value "<pick dir>"
Ensure that the following conditions are satisfied for the input directory :
1) It exists and is a directory (not a file). and
2) It is readable (file read permissions). and
3) If activation parameter "DeleteFile" is set to "true" then the directory should also have granted write permissions. and
4) If using a logical name, then ensure that the mapping from logical name<->physical directory is correctly specified in the deployment descriptor.

]]

Cause

To view full details, sign in with your My Oracle Support account.