My Oracle Support Banner

Password Change In OIM Is Not Updated In SAP Target System (Doc ID 2423075.1)

Last updated on AUGUST 11, 2021

Applies to:

Identity Manager - Version 12.2.1.3.180116 and later
Information in this document applies to any platform.

Symptoms

OIM: 12.2.1.3.180116
SAP User Management Connector: 11.1.1.6

When the password is reset in OIM, but it is not updated in the SAP target system with the following error.

IAM-3056160:Modify User Profile request cannot set or change attribute Password, since it is not defined in the corresponding data set.

STEPS
-------

1. Setup SAP UM Connector and configure it according to the connector guide.
2. Provision SAP Account to a test user.
3. Change user's password in OIM using Reset Password button on Accounts tab.
4. The password is updated in OIM, but fails to update in SAP.


Changes

The process task "Change User Password" does not exist out of the box in SAP User Management Connector. It was created and configured manually.

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.