My Oracle Support Banner

Can Not Change AOB Attribute Width In "Schema" Tab (Doc ID 2528571.1)

Last updated on JULY 27, 2023

Applies to:

Identity Manager - Version 12.2.1.3.0 to 12.2.1.3.190109 [Release 12c]
Information in this document applies to any platform.

Symptoms

In an AOB (application on-boarded) connector in OIG 12c, there is no supported way in the UI to change a field width in the "Schema" tab.

Additionally, if you go into Design Console (which you should not for AOB apps in OIG 12c) and change the field width in the application process form and run "Create Reconciliation Profile" then the applications process form width will change in the process form table (i.e. UD_*) but not the reconciliation staging table (i.e. RA_*).  When a reconciliation is then run for the application you may see an error similar to:

java.sql.SQLException: ORA-12899: value too large for column "<SCHEMA_NAME>"."RA_<STAGING_TABLE>"."<STAGING_TABLE_COLUMN>"

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!