Symptoms

When running an OWB Process Flow or Mapping on a RAC, the following error might occur when one of the RAC instances goes down:

ORA-25408: Can Not Safely Replay Call.


Description of the error:

Error: ORA-25408
Text: can not safely replay call
---------------------------------------------------------------------------
Cause: The connection was lost while doing this call. It may not be safe to replay it after failover.
Action: Check to see if the results of the call have taken place, and then replay it if desired.