Comverse Insight-SRL Cartridge(Comversesrl_3_x) Did Not Generate Connection Lost Exception
(Doc ID 1182235.1)
Last updated on JUNE 21, 2022
Applies to:
Oracle Communications ASAP Cartridges - Version 1.0.0 and laterInformation in this document applies to any platform.
Symptoms
On Comverse SRL 3 Technology Cartridge,
User found that the cartridge did not generate a connection lost exception when the network element did not respond to a request. The read timeout was configured as 30 seconds, with the understanding that if the network element did not respond in 30 seconds, then the cartridge should throw a connection lost exception. Disconnection of the existing connection also did not happen after configured drop_timeout parameter. it was configured as 1 min.
Workaround is to restart the NEP server to disconnect the connection.
EXPECTED BEHAVIOR
-----------------------
Expect that cartridge should have thrown connection lost exception and would have retried with new connection