Indirect Rehome Process Could Not Find End Component

(Doc ID 2226834.1)

Last updated on JANUARY 25, 2017

Applies to:

Oracle Communications MetaSolv Solution - Version 6.2.1 and later
Information in this document applies to any platform.

Symptoms

PROBLEM STATEMENT

On : 6.2.1.1005.b13 version, Engineering - Indirect Rehome process

After creating an Indirect Rehome project for an EVC and trying to Process Groom get following error.

Indirect Rehome validation - Could not find End Component from Assign Connection

The issue is similar but not the same as SR 3-12647930321, raised before.
Both were raised by users and Prod Mgmt has validated them.

STEPS

The issue can be reproduced at will with the following steps:

1. Create Network Groom for a virtual circuit

2. Create EWO from new Network Groom project
3. When trying to Process Groom from Work Queue Manager get following error.

ERROR

Indirect Rehome validation - Could not find End Component from Assign Connection

BUSINESS IMPACT

Users are unable to groom EVC’s to other Network circuits.

Cause