UIM 7.4.1|"Associate Logical Device" Tab "Specification" Drop-down Does Not Show All Parent LD Specifications
(Doc ID 2848174.1)
Last updated on NOVEMBER 13, 2023
Applies to:
Oracle Communications Unified Inventory Management - Version 7.4.1.0.0 and laterInformation in this document applies to any platform.
Symptoms
On : 7.4.1.0.0 version, Logical Devices
*********************************
ACTUAL BEHAVIOR
-----------------------------
Under "Associate Logical Device" tab "Specification" drop-down does not show all LD specifications .
Created LogicalDevice, and have to associate it to the ParentLogical Device of particular specification. But ,while associating Parent LogicalDevice to the child LogicalDevice in "Associate Logical Device" tab , the "Specification" drop-down does not show all the available LogicalDevice specifications.
EXPECTED BEHAVIOR
---------------------------------
While associating Parent LogicalDevice to the child LogicalDevice in "Associate Logical Device" tab "Specification" drop-down should show all the available LogicalDevice specifications.
STEPS
------------
The issue can be reproduced at will with the following steps:
1-Create 4 LD Specs in Design Studio (Say LD1,LD2,LD3,LD4). Make LD1, LD2,LD3 as parent specs for LD4.
2-In UI ,create LogicalDevice based on LD4.
3-Try to associate it to the ParentLogical Device.While associating Parent LogicalDevice to the child LogicalDevice in "Associate Logical Device" tab "Specification" drop-down does not show all the available parent LogicalDevice specifications. Only one is coming up currently
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |
References |