My Oracle Support Banner

Unable to receive dual UOM item with 1 piece of secondary quantity (Doc ID 2578031.1)

Last updated on AUGUST 24, 2023

Applies to:

Oracle Fusion Inventory Management Cloud Service - Version 11.13.19.04.0 and later
Information in this document applies to any platform.

Symptoms

When business user is trying to receive one material with one each which is secondary UOM,System pops up the below error. 

  

They have following Setup:

Business defined dual UOM item with defaulting control 'Fixed'.

Also standard UOM conversion configured between primary and secondary UOM. One BOX35 is equal to 35 Each

Checked the standard UOM conversion where conversion has been defined as below

Base UOM Conversion Class Name UOM name

Each 35 Quantity BOX35

At item#XYZ was setup as below

Primary Unit of Measure= BOX35

Tracking Unit of Measure=Primary and secondary

Pricing=Primary

Conversion=Both

Secondary Unit of Measure=Each

Defaulting Control=Fixed

Positive Deviation Factor=0

Negative Deviation Factor=0

  

ERROR

'The difference in primary and secondary quantities is exceeding the deviation limit for the item. Adjust the quantities not to exceed the deviation limit. (INV-2416220)'


STEPS


1. Create dual UOM item with defaulting control Fixed

2. Configure standard UOM conversion between primary and secondary UOM

3. Create transfer order in destination inventory org and ship from source inventory org

4. Receive the material in destination inventory org

5. Observe the reported error

Cause