Errors ORA-39006 ORA-39068 ORA-16224 ORA-39097 Raised During DataPump Export With Logical Standby Dataguard Guard_Status Set to ALL (Doc ID 1236184.1)

Last updated on MARCH 19, 2012

Applies to:

Oracle Server - Enterprise Edition - Version: 10.2.0.4 and later   [Release: 10.2 and later ]
Information in this document applies to any platform.
***Checked for relevance on 19-MAR-2012***

Symptoms

The following errors are seen during execution of Datapump export:

ORA-39006: internal error
ORA-39068: invalid master table data in row with PROCESS_ORDER=-3
ORA-16224: Database Guard is enabled
ORA-39097: Data Pump job encountered unexpected error -16224

The logical standby Dataguard GUARD_STATUS has the value ALL. This value can be confirmed by the following query:

SQL > select guard_status from v$database;

Cause