RAC and Standalone Environments, using ASM with ACFS, can be affected with kernel panics caused by OKS Module, in association with IBM Scanners or Other Scanners (20140148)
(Doc ID 1615298.1)
Last updated on FEBRUARY 18, 2022
Applies to:
Oracle Database Cloud Service - Version N/A and laterOracle Database - Enterprise Edition - Version 11.2.0.3 to 12.1.0.2 [Release 11.2 to 12.1]
Oracle Database Cloud Schema Service - Version N/A and later
Oracle Database Exadata Express Cloud Service - Version N/A and later
Gen 1 Exadata Cloud at Customer (Oracle Exadata Database Cloud Machine) - Version N/A and later
Information in this document applies to any platform.
Symptoms
So far, the issue is mainly encountered with IBM Port Scanners. However, there is a possibility that other SSL Scanners' checks can cause the issue.
PLEASE NOTE: Any scan that probes the port that the ACFS daemon uses is affected...NOT just IBM Port Scanners.
1) If on the Environment the scan script runs with IBM Port Scanners turned on, the Server/Node crashes with an OKS module panic call that is caused by OKS Module:
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
History |
Solution |
Workaround |
Patches |
Community Discussions |
References |