Symptoms

FAN events are not being broadcast by the ONS process in the Grid CRS home

 

Database FAN events do not work.

$ java -Doracle.ons.oraclehome=$CRS_HOME fanWatcher nodes=${NODES}
Subscribing to events of type:
Opening FAN Subscriber Window ...

Only ONS update events shown

** Event Header **
Notification Type: ONSupdate
Delivery Time: Thu Jun 08 08:35:14 CEST 2023
Creation Time: Thu Jun 08 08:35:14 CEST 2023
Generating Node: <hostname.domainname>
Unknown event type. Not displaying body

All listeners (regular and SCAN) on the server are logging the following message every minute:

 Connection using service may fail with ORA-12514

Changes

 All started after 19.17 DBRU

Cause