WIP Assembly Completions Fail in Transactions Open Interface When Having Push Serialized Components (Doc ID 1069392.1)

Last updated on MARCH 08, 2017

Applies to:

Oracle Work in Process - Version 12.0.0 and later
Information in this document applies to any platform.
***Checked for relevance on 31-May-2013***

Symptoms


When using mtl_transactions_interface to perform WIP Component Issue and WIP Assembly Completion for jobs, completion transaction fails with the following error message:

Error
--------


"An assembly transaction cannot be processed in background mode if it has backflush components that are serial controlled or lot controlled where the lot cannot be derived."



When worker runs, both issue and completion records reside in mtl_transactions_interface. WIP Component Issue is processed, completion remains in the table with the error message.

However if resubmit afterward completion transaction completes fine. It is a timing issue.

Tried with different scenarios, the error message appears when the job contains serialized component.
Even when ALL components have Push supply type, so no backflush happens.