MWA Assembly Completion Error For Serial Longer Than 30 Chars - BatchUpdateException: ORA-12899: Value Too Large For Column "INV"."MTL_SERIAL_NUMBER
(Doc ID 2885976.1)
Last updated on JULY 27, 2022
Applies to:
Oracle Inventory Management - Version 12.2.11 and laterInformation in this document applies to any platform.
Symptoms
On : 12.2.11 version, Lot and Serial Management
Find following upgrade from 12.2.9 to 12.2.11 there is an issue with the MWA Assembly Completion process.
If the user enters a serial number longer than 30 characters, the following error appears:
After that, even if user enters a correct serial number (less than 30 characters), the same error appears
After the error appears, the completion transaction for any serial number cannot be performed, only after bounce the mobile server, work can be continued.
Error
'Error :java.sql.BatchUpdateException: ORA-12899: value too large for column "INV"."MTL_SERIAL_NUMBERS"."SERIAL_NUMBER" '
Steps
Paths to functionalities where problem exists:
1. Whse Mgmt -> Manufacturing -> Assy & Material Txn -> Complete Assy -> Complete
2. Whse Mgmt -> Manufacturing -> LPN Txn -> Assy Completion ->Assy Completion
1. Enter Job, Sub, Loc, Qty
2. In field SN enter serial number longer than 30 characters, for example : 000042363838000042363838000042363838. Error appears: 'Error :java.sql.BatchUpdateException: ORA-12899: value too large for column "INV"."MTL_SERIAL_NUMBERS"."SERIAL_NUMBER" '
3. In field SN enter serial number enter serial number less than 30 characters, for example : 000042363838. Error appears: 'Error :java.sql.BatchUpdateException: ORA-12899: value too large for column "INV"."MTL_SERIAL_NUMBERS"."SERIAL_NUMBER" '