DDLDict Utility Fails with GEN-14: More than one primary key column for table! in export_logical_schema.log in PostInstallDbSetup
(Doc ID 2793308.1)
Last updated on NOVEMBER 24, 2022
Applies to:
Siebel CRM - Version 21.6 and laterInformation in this document applies to any platform.
Symptoms
Applied Siebel 2021.6 and PostInstallDbSetup failed.
In PostInstallDbSetup_date_time.log:
Thu Jul 8,2021 [14:39:0] : Stage 2 of 3 : Running SeedSchemaManifest Upgrade
Thu Jul 8,2021 [14:48:41] : Return Code from SeedSchemaManifest Upgrade : Failed
In the export_logical_schema.log:
GenericLog GenericError 1 0000000260f51db4:0 2021-07-19 11:45:33 Message: GEN-14,
Additional Message: More than one primary key column for table!
SQLDBUtilityLog SQLDBUtilityLog 3 0000000260f51db4:0 2021-07-19 11:45:33 Unable to load dictionary data.
SQLDBUtilityLog SQLDBUtilityLog 3 0000000260f51db4:0 2021-07-19 11:45:33 Error in DDLDictStartApis function..
GenericLog GenericError 1 0000000260f51db4:0 2021-07-19 11:45:33 (logapi.cpp (184) err=1 sys=2) SBL-GEN-00001: (logapi.cpp: 184) error code = 1, system error = 2, msg1 = (null), msg2 = (null), msg3 = (null), msg4 = (null)
When trying to do a FullPublish, in siebdev.log:
ObjMgrBusCompLog Error 1 0000000260f03d3c:0 2021-07-15 11:07:10 (oracon.cpp (5001)) SBL-DBC-00111: An error has occurred writing to a record.
Please continue or ask your systems administrator to check your application configuration if the problem persists.
SQLParseAndExecute Execute 5 0000000260f03d3c:0 2021-07-15 11:07:10 ORA-00904: "T4"."MODE_CD": invalid identifier
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |