EAI Siebel Adapter Question - "missing header properties" (Doc ID 514679.1)

Last updated on MARCH 02, 2017

Applies to:

Siebel System Software - Version 7.5.2.214 SIA [16066] and later
Siebel CRM - Version 7.5.3 SIA [16157] and later
z*OBSOLETE: Microsoft Windows 2000
Version: 7.5.2.214 [16066] Life Sci
Database: Oracle 8.1.7.4
This document was previously published as Siebel SR 38-1212824447.
***Checked for relevance on 28-JUN-2016***


Symptoms

SBL-EAI-04024

A custom Business Service was used to invoke EAI Siebel Adapter, Query :-

Function Service_PreInvokeMethod (MethodName As String, Inputs As PropertySet, Outputs As PropertySet) As Integer
    
Dim oBSObj         As Service
Dim oInput        As PropertySet
Dim oOutput        As PropertySet
Dim oChild        As PropertySet

Set oBSObj = theApplication.GetService("EAI Siebel Adapter")
Set oInput = theApplication.NewPropertySet()
Set oOutput = theApplication.NewPropertySet()
Set oChild = theApplication.NewPropertySet()

Input.SetProperty "NumOutputObjects", ""
Input.SetProperty "OutputIntObjectName", "Test Plan Team"
Input.SetProperty "PrimaryRowId", "1-FWXKU"

oChild.SetType "SiebelMessage"
oChild.SetProperty "MessageId",""
oChild.SetProperty "MessageType","Integration Object"
oChild.SetProperty "IntObjectFormat","Siebel Hierarchical"
oChild.SetProperty "IntObjectName","Test Plan Team"

Input.AddChild oChild

oChild.Reset

BSObj.InvokeMethod "Query", oInput, oOutput

Set oBSObj = Nothing
Set oInput = Nothing
Set oOutput = Nothing
Set oChild = Nothing

Service_PreInvokeMethod = CancelOperation

End Function

Following error was returned :-

[0] Input Message is missing header properties (SBL-EAI-04024)

Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms