Sun SPARC Enterprise T5440 Server: Power system fault detected at /SYS/MB/CPUx/DVRM_15: status 0x4

(Doc ID 1502146.1)

Last updated on JANUARY 05, 2018

Applies to:

Sun SPARC Enterprise T5440 Server - Version All Versions and later
Information in this document applies to any platform.


During HOST power on/off  (ILOM cli, start /SYS or stop /SYS), D210 DC/DC Converter on some cpu modules have a false 00VP trip, which is reported as a (DVRM_15/00V_+1V5) asserted failure that is captured by firmware.  The SP then power cycles the host. 

example (from ALOM-CMT's "showlogs -v"):

Chassis |critical: "Host has been powered off"
Chassis |major : "/SYS/MB/CPU0/DVRM_15/OOV_+1V5: asserted failure"
Chassis |major : "Power system fault detected at /SYS/MB/CPU0/DVRM_15: status 0x4"
Fault |critical: "SP detected fault at time Mon Jul 11 14:04:26 2011. Host Power Failure: MB_DC_POK Fault"


Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms