"Eject" button does not work on internal DAT72 drive. (Doc ID 1516187.1)

Last updated on MARCH 29, 2017

Applies to:

Sun Netra 1290 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M4000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M5000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M8000 Server - Version All Versions to All Versions [Release All Releases]
Sun SPARC Enterprise M9000-32 Server - Version All Versions to All Versions [Release All Releases]
Information in this document applies to any platform.

Symptoms



To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - SPARC Legacy Servers



When trying to eject the cartridge from internal DAT72 drive using the eject button, it does not work. 

When using the command from Solaris, the cartridge is ejected:

This behaviour was observed with PN: 380-1324 [F] DAT 72 Internal Tape Drive, 5.25 inch/68 pin SCSI in a Sun Fire V890 Server, though if the behavior is seen in other DAT drives the Solution should be the same.

Please note that 380-1324 DAT72 drive can be installed by default on different platforms; you may check this by using the Oracle System Handbook "search" tab (searching for platforms where 380-1324 can be installed).

 

Cause