SL150 - Error : "Magazines Not Latched" 9081, Library Will Not Initialize Due to Serial Number Mismatch
(Doc ID 1539657.1)
Last updated on JULY 25, 2022
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform.
Note:
As each component is replaced, such as Robot, Op Panel, KLM. Serial number can be lost without a successful library initialization between part replacement. Reason is the flash stick housing library serial number are in these 3 locations and 2 of 3 flash sticks must match, otherwise library will not initialize without taking drastic steps of remotely re-programming the flash stick using Eng userid (only L2 and engineering) using webex session.
*** Workaround ***If for any reason the replacement part did not fix the problem and did not initialize library, put the original part back in and capture a log bundle. Engage L2 support before replacing another part.
Symptoms
Final code 9081:
Decoded:
9081 MAG_MULTIPLE_OPEN_OR_UNLATCHED Multiple magazines have been opened or unlatched.
Result code 9081, RC9081, FSC9081
Library will not initialize.
2013-02-25T16:35:39.698, 0.0.0.0.0, 000, sensor-manager, , error, 0000, 0000, "getCheckProductIDSN: Base KLM no SN no match in KLC and KLO"
2013-02-25T16:35:39.699, 0.0.0.0.0, 000, sensor-manager, , error, 0000, 0000, "SensorMgr - setting library InOp due to Product ID issues!"
Replaced the robot and magazines but did not resolve the issue.
The actual error can be misleading as the problem is related to a serial number issue.
Changes
New install. Multiple parts replaced on SL150.
Cause