Sun Storage 7000 Unified Storage System: Communication with the cluster peer via a cluster interconnect link has been lost (Doc ID 1542550.1)

Last updated on MARCH 16, 2017

Applies to:

Sun ZFS Storage 7320 - Version All Versions to All Versions [Release All Releases]
Sun Storage 7410 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun Storage 7310 Unified Storage System - Version All Versions to All Versions [Release All Releases]
Sun ZFS Storage 7420 - Version All Versions to All Versions [Release All Releases]
Oracle ZFS Storage ZS3-2 - Version All Versions to All Versions [Release All Releases]
7000 Appliance OS (Fishworks)

Symptoms

To discuss this information further with Oracle experts and industry peers, we encourage you to review, join or start a discussion in the My Oracle Support Community - Disk Storage ZFS Storage Appliance

 

NOTE: To confirm that the cluster 'links' cabling is correctly configured - See Document ID 2081179.1

 

Alerts mentioned below may be seen on 7000 Series ZFS Storage Appliance working in a cluster configuration.

Issue reported on AK firmware version: 2011.1.x

SUNW-MSG-ID: AK-8001-RK, TYPE: alert, VER: 1, SEVERITY: Minor
EVENT-TIME: Thu Jan 31 15:42:59 2013
PLATFORM: i86pc, CSN: <serialno>, HOSTNAME: <hostname>
SOURCE: svc:/appliance/kit/akd:default, REV: 1.0
EVENT-ID: 665840e4-94f8-6516-eb1a-f90c0edd0c59
DESC: Communication with the cluster peer via a cluster interconnect link has been lost.
AUTO-RESPONSE: None.
IMPACT: Cluster reliability is impaired.  If the cluster peer is functioning normally but no cluster interconnects remain active, arbitrary and unwanted cluster takeover may occur.
REC-ACTION: Check the cluster interconnect cables and the state of the cluster peer.  Contact your vendor for support if an interconnect link remains inexplicably down.


But, no takeover or reboot or any other cluster interconnect related issues are seen.


Peer head seems to be working fine - without any issues.

 

PLEASE NOTE:  After upgrade to 2013.1.6.0, 'cluster link down' alerts are reported even on a 'normal' reboot.

See MOS Doc ID 2195659.1 (See also - Bug 23092294 clustron component fault shows up in problems while links are still active)

 