SL500 - Drive Targeting Errors - Drives "Inop" in SLConsole, Result Code 5501
(Doc ID 1545354.1)
Last updated on JULY 25, 2022
Applies to:
Sun StorageTek SL500 Modular Library System - Version All Versions and laterHP LTO4 Tape Drive - Version All Versions and later
HP LTO5 Tape Drive - Version All Versions and later
HP LTO6 Tape Drive - Version All Versions and later
Information in this document applies to any platform.
Symptoms
All four drives are shown as inoperative on SL500.
The EventLog will show targeting errors on the robot like Result Code:5501 in all the drives. However, the robot is fine. RC5501, 5501
2013-02-22 17:53:30 Drive_Bay3(0,2,1,9)
5501 - (4X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,2,1,9, result code=5501
(Errors Started - 2013-02-13 13:45:24 Errors Stopped - 2013-02-22 17:53:30)
2013-02-22 17:52:01 Drive_Bay4(0,2,2,9)
5501 - (4X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,2,2,9, result code=5501
(Errors Started - 2013-02-13 13:45:52 Errors Stopped - 2013-02-22 17:52:01)
2013-02-21 18:22:58 Drive_Bay2(0,1,2,9)
5501 - (3X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,1,2,9, result code=5501
(Errors Started - 2013-02-13 13:44:55 Errors Stopped - 2013-02-21 18:22:58)
2013-02-21 18:22:31 Drive_Bay1(0,1,1,9)
5501 - (3X)
Director - auditResponse() : cmo_user_audit: Failed target calibration for (LMRC) 0,1,1,9, result code=5501
(Errors Started - 2013-02-13 13:44:28 Errors Stopped - 2013-02-21 18:22:31)
Changes
This issue will unlikely take place in a working library. It will happen in a new install.
The customer installed the SL500 themselves following the instructions. However the drive bezels were not delivered by mistake.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |