Information in this document applies to any platform.
New SL150 Installation
10 Module SL150 configuration.
1.82 Firmware

Symptoms

During initialization the following series of errors are seen in the error logs and the library does not go online (goes inop).

This is accompanied by multiple robot reach / put type errors. e.g. 5121, 3202 etc.

2013-05-13T19:08:02.138    0000    0.0.0.0.0    1228     "Director - initResponse() directorSelfInit; MCI Module Count is Greater than Z Range for Modules Calculation: MCI ModCnt=10, Z Sweep ModCnt=1; End of Text"             /usr/local/bin/Ifm     519                robot      error
       2013-05-13T19:08:02.143    0100    0.0.0.0.0    1228     "IfmInitThread:Failure to Initialize...reason==The number of KLEs seen by MCI does not match Z's range for Modules - GOING INOP"                                  3202                  ifm      error
       2013-05-13T19:08:03.160    3750    0.0.0.0.0    3755     "Process /usr/local/share/sbin/snmptrapd murdered by signal 11"                                  3750           processMgr      error


Changes

 The library was newly installed.

Cause