SL150 - Message "The Number of KLEs Seen by MCI Does Not Match Z's Range for Modules - GOING INOP" MSG 3203 Issued During Initialization
(Doc ID 1554285.1)
Last updated on JULY 25, 2022
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform.
New SL150 Installation
10 Module SL150 configuration.
1.82 Firmware
Symptoms
During initialization the following series of errors are seen in the error logs and the library does not go online (goes inop).
This is accompanied by multiple robot reach / put type errors. e.g. 5121, 3202 etc.
2013-05-13T19:08:02.138 0000 0.0.0.0.0 1228 "Director - initResponse() directorSelfInit; MCI Module Count is Greater than Z Range for Modules Calculation: MCI ModCnt=10, Z Sweep ModCnt=1; End of Text" /usr/local/bin/Ifm 519 robot error
2013-05-13T19:08:02.143 0100 0.0.0.0.0 1228 "IfmInitThread:Failure to Initialize...reason==The number of KLEs seen by MCI does not match Z's range for Modules - GOING INOP" 3202 ifm error
2013-05-13T19:08:03.160 3750 0.0.0.0.0 3755 "Process /usr/local/share/sbin/snmptrapd murdered by signal 11" 3750 processMgr error
Changes
The library was newly installed.
Cause