Diameter Signaling Router (DSR) 5.0 syscheck "ntp: FAILURE:: File has corrupted value for time "
(Doc ID 1927810.1)
Last updated on AUGUST 21, 2023
Applies to:
Oracle Communications Diameter Signaling Router (DSR) - Version DSR 5.0 to DSR 6.0 [Release DSR 5.0 to DSR 6.0]Tekelec
Syscheck errors:
[root@drfa-dsrNO-b]# syscheck
Use of uninitialized value $time in pattern match (m//) at /usr/TKLC/plat/lib/Syscheck/modules/proc/ntp/Test.pm line 786.
Use of uninitialized value $time in concatenation (.) or string at /usr/TKLC/plat/lib/Syscheck/modules/proc/ntp/Test.pm line 788.
Running modules in class disk...
OK
Running modules in class hardware...
OK
Running modules in class net...
OK
Running modules in class proc...
* ntp: FAILURE:: File has corrupted value for time
* ntp: FAILURE:: TIME:
* ntp: FAILURE:: Could not get last good time info
One or more module in class "proc" FAILED
Running modules in class system...
OK
LOG LOCATION: /var/TKLC/log/syscheck/fail_log
Purpose
Clear NTP alarms from syscheck, caused by /var/TKLC directory at 100%
Troubleshooting Steps