HP LTO5/SL8500 -All Library Attached HP LTO5s Fail When Reboot via SLC After ADI Eenabled
(Doc ID 1941994.1)
Last updated on JULY 25, 2022
Applies to:
HP LTO5 Tape Drive - Version All Versions and laterSun StorageTek SL8500 Modular Library System - Version Not Applicable to Not Applicable [Release N/A]
Information in this document applies to any platform.
Information of version:
SL8500 : FRS 8.35
HP LTO5 : I5BS-015.762
Symptoms
To enable ADI, FE rebooted the SL8500 and then rebooted all HP LTO5s via SLConsole.
All HP LTO5s had following errors and went down.
2014-10-23T07:53:17.789, 1.0.0.0.0, root, default, reboot, 196501, warn, 9995, "Reboot requested - local request", parameters="client=localhost, device=1,2,-2,1,2, requester=default"
2014-10-23T07:53:37.022, 1.1.-2.1.2, root, default, internal, 0, error, 1303, "Failure from drive Code: 000 - ok", Data:=<response sequence="22771" final="true"><command>controlPower</command><result identifier="1"><resultStatus><resultSeverity>error</resultSeverity><resultCode>6202</resultCode><resultText><!|CDATA|End of Text||></resultText><operationalState>000</operationalState></resultStatus></result></response>
2014-10-23T07:53:37.302, 1.0.0.0.0, root, default, internal, 0, error, 3206, "Device response inconsistent - OperationalState zero and severity is error"
2014-10-23T08:07:39.053, 1.0.0.0.0, root, default, AuditDaemon,-1060701, error, 3324, "Audit cannot complete due to hardware failure com.stortek.ats.elib.server.common.LcException: Drive not found - unknown drive type in audit: 1,2,-2,1,2", startAddress=1,2,-2,1,2 endAddress=1,2,-2,1,2
Changes
Rebooted the HP LTO5s via SLConsole.