SL150 - Tape Library In Inoperative State, Error 0.0.0.0.0 9009 "PS FAULT (Module Power Supply AC OK Line Indicates a Failure)
(Doc ID 2145429.1)
Last updated on JULY 25, 2022
Applies to:
StorageTek SL150 Modular Tape Library - Version All Versions and laterInformation in this document applies to any platform.
Symptoms
Tape library in Inoperative State
Found several P/S failures:
Current Power Supplies
ID Present Status
1 true Inoperative
2 true Inoperative
3 true Operative
4 true Operative
5 true Inoperative
6 true Inoperative
2016-05-22T09:49:44.745 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:55:11.487 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:58:22.892 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:13:09.129 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:15:07.254 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:16:56.155 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:19:58.867 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:22:06.039 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:50:30.981 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:56:35.914 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:03:32.329 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:16:49.437 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:20:36.154 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:25:24.386 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:29:02.705 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:1 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:51:52.366 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:54:24.567 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:02:48.313 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:22:17.967 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-25T10:26:34.614 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:1, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:52:51.906 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T09:55:41.609 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:02:13.942 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:05:39.919 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:08:40.591 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:11:24.248 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:15:16.187 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
2016-05-22T10:21:10.017 error 0.0.0.0.0 9009 "PS FAULT (Module power supply AC OK line indicates a failure): module:2 position:2, statusWord:0xFFFF, firmwareVersion:0x525"
Modules 1 and 3 has no power supply operational.
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
Applies to: |