Problem Summary
---------------------------------------------------
Test IMT Bus command Failed

Problem Description
---------------------------------------------------
As part of the Health Check procedure in Section "3.21 Testing IMT Status" I inhibited IMT Bus A, and when I issued the "tst-imt:type=faulttest:bus=A" in command 5 I receive a "Phased 2 failed" log.

> tst-imt:type=faulttest:bus=a

  eaglestp 16-09-25 11:33:01 EST EAGLE 46.3.0.0.1-68.27.0
  tst-imt:type=faulttest:bus=a
  Command entered at terminal #23.
;
 
 Command Accepted - Processing
  eaglestp 16-09-25 11:33:03 EST EAGLE 46.3.0.0.1-68.27.0
  Notice: IMT fault test terminated.
  Non-standard cabling or IMT Bus A state change detected.
  Card range 1107 - 1217.
  Non-standard cabling or IMT Bus A state change detected.
  Card range 1201 - 1113.
  
;
  eaglestp 16-09-25 11:33:03 EST EAGLE 46.3.0.0.1-68.27.0
  Phase 2 failed
;
  eaglestp 16-09-25 11:33:03 EST EAGLE 46.3.0.0.1-68.27.0
  Command Completed.
 