Symptoms
"Cisco UCS Fabric Interconnect" is not presenting NPIV ports on port 1/4 of Brocade DCX 8510-4 Backbone (FOS v7.3.1a)
but presenting correct information on port 1/44
switchshow:
Changes
Customer replaced an SFP in Brocade Switch port 1/4 where a "Cisco UCS Fabric Interconnect" is connected (also connected to port 1/44)
Now the Brocade Switch is not detecting the NPIV virtual WWNs of Cisco UCS servers on that port 1/4, but presenting right information on the other port 1/44