My Oracle Support Banner

VSM5 - RTD is showing message errors 3627. (Doc ID 2243929.1)

Last updated on JULY 25, 2022

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Customer messages log:

01:02:40.87 STC23901 00000010 .SLS0923I DRIVE 3F86 HAS BEEN CLEANED USING CLN100
.SLS6684I RTD V0023F86 ON VTSS VSM002 RETURNED ECAM ERROR CC=5 RC=108
.SLS6625E RTD V0023F86 REPORTED TAPE VOID: 08402031000000203700>3627<000000000000000000000000CE0E522009510000

SL8500 log is show:

2017-03-11T04:18:27.020 warn 1.2.-2.1.2 3992 "Warning from device", Data=!|CDATA|drive 1,2,-2,1,2: load Successful with unitCheck 3627: CartLabel: CLN100CL (sn = 572004005344)||
2017-03-11T04:20:02.555 warn 1.2.-2.1.2 3992 "Warning from device", Data=!|CDATA|drive 1,2,-2,1,2: rewindUnload Successful with unitCheck 3627 (cartLabel = CLN100CL)||

 

MODEL = T10000B
FSC = 3627
FSC Match Found in Rev. 1.52)

FSC: 3627 RO_FSC_HANDLE_NEED_READ_DATA_FOR_BLANK_TAPE

MIM Code: NONE

FRU: OPER. ERROR CONF: 100%

Summary: |BLANK TAPE READ | *** | *** |

Field Text:
The drive was asked to read a blank tape.

 

Changes

 

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!