T10000C - Drive Got Reset After DUMP FSC 4969
(Doc ID 2382106.1)
Last updated on JULY 25, 2022
Applies to:
StorageTek T10000C Tape Drive - Version All Versions and laterInformation in this document applies to any platform.
Symptoms
T10000C - Drive Got Reset After DUMP FSC 4969
Drive: 576004008921
Type: T10000c
Version: 3.64.101-5.50 Last Updated 2018-04-03 12:02:17
2018-04-03 07:00:42 (SA-365) Analysis of logs detected fatal drive error (SNO) has occurred due to down level microcode. These SNO (Should Not Occur) errors will cause the drive to stop communicating with the host and automatically force a drive dump. The drive will come back online after it IPLs. This action will also cause the current tape job to terminate.
This drive has microcode that is down level by several revisions and is considered unsupported microcode. It is highly recommended to upgrade the drive microcode, at your earliest convenience, on all drives of this model to the current microcode version 3.65.103. <----------------------------------- Up level firmware.
Drive Microcode When the Failure Occurred: 3.64.101
SNO FSC: 4969
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |