SL8500/T10000B - Drive Issue FSC 5C3B, BRUSH_FSC_MIN_SHIELD_UP_MOTION_TIMEOUT (Doc ID 2427863.1)

Last updated on JULY 25, 2022

Applies to:

Sun StorageTek T10000B Tape Drive - Version All Versions to All Versions [Release All Releases]
Sun StorageTek SL8500 Modular Library System - Version All Versions and later
Information in this document applies to any platform.

Symptoms

Rewind-unload FAILED with unit-check 5C3B.

Drive: Investigate HW: 1.1.-2.1.4 Tray Serial: 572000204xxx HLI: X.0.1.3

1.1.-2.1.4 52 5 T10000b StorageTek loaded 1.52.206-5.30 warn

HW Address: 1.1.-2.1.4
Total EWI Count for 1.1.-2.1.4: 89
Error Reason(s):
Warning Reason(s): 1107
Drive Type: T10000b
Bay: Drive_Bay52
HLI Address: X.0.1.3
Vendor: StorageTek
Partition ID: N/A
EWI Messages:

Drive_Bay52(1.1.-2.1.4)

1107 - (35X)
Drive not unloaded for fetch - on rewindUnload, hliLsm=0
(Errors Started - 2018-07-14 18:58:18 Errors Stopped - 2018-07-18 07:16:12)

1303 - (8X)
Failure from drive Code: 601 - Drive is loaded, drive 1,1,-2,1,4: rewindUnload FAILED with unitCheck 5C3B - drive is loaded (, driveType = T10000b, driveFirmware = 1.52.206-5.30)122</cartridg
Failure from drive Code: 601 - Drive is loaded, drive 1,1,-2,1,4: rewindUnload FAILED with unitCheck 5C3B - drive is loaded (, driveType = T10000b, driveFirmware = 1.52.206-5.30)17</cartridgeL

VOLSERS seen in 1303 messages: R01436T1 (x8)
(Errors Started - 2018-07-15 06:03:56 Errors Stopped - 2018-07-18 09:30:36)

3287 - (2X)
Device transitioned to not ready, address=(Drive_Bay52)1,1,-2,1,4
(Errors Started - 2018-07-17 07:12:27 Errors Stopped - 2018-07-17 07:14:19)

3955 - (43X)
Error from device Code: 601 - Drive is loaded, drive 1,1,-2,1,4: rewindUnload FAILED with unitCheck 5C3B - drive is loaded (, driveType = T10000b, driveFirmware = 1.52.206-5.30)122</cartridgeLifeP
Error from device Code: 601 - Drive is loaded, drive 1,1,-2,1,4: rewindUnload FAILED with unitCheck 5C3B - drive is loaded (, driveType = T10000b, driveFirmware = 1.52.206-5.30)17</cartridgeLif

VOLSERS seen in 3955 messages: R01436T1 (x43)
(Errors Started - 2018-07-14 18:58:18 Errors Stopped - 2018-07-18 09:30:36)

DRIVE FSC:
--------------------

FSC Encountered: 5C3B Drive: 1.1.-2.1.4 Volser: R01436T1

(FSC Match Found in Rev. 1.52)
FSC: 5C3B BRUSH_FSC_MIN_SHIELD_UP_MOTION_TIMEOUT
MIM Code: NONE

FRU: HARDWARE CONF: 100%

Summary: |HEAD BRUSH |INTERCONNECT |POWER AMP |

Field Text:
A timeout occurred while attempting to move to the min shielded
position.

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!