Goal
Customer would like to know the relationship between "ETG Rate Limit Degraded" and "AbatementTime".
===========================
"ETG Rate Limit Degraded"
ID:22057
"AbatementTime;"
Main Menu: Diameter -> Configuration -> Configuration Sets -> Rate Limiting Configuration Sets
===========================
We did the examination, the result is as follows.
1.)When AbatementTime is 1000msec and traffic exceeds MaximumEgressRequestRate.
Alarm(ID:22057 ETG Rate Limit Degraded) occurred and Clear alarm were repeated every 30 sec.
00:00:00 Alarm occurred
00:00:20 Clear Alarm
00:00:30 Alarm occurred
00:00:50 Clear Alarm
00:01:00 Alarm occurred
2.)When AbatementTime is 10000msec and traffic exceeds MaximumEgressRequestRate.
Alarm(ID:22057 ETG Rate Limit Degraded) occurred, 140sec later Claer Alarm.
Next Clear Alarm 900 sec later.
00:00:00 Alarm occurred
00:02:20 Clear Alarm
00:02:30 Alarm occurred
00:17:30 Clear Alarm
00:17:40 Alarm occurred