New 6350 - HW Diags Failed - TestBoomer0Oct1DdrRandomXor
(Doc ID 2741363.1)
Last updated on OCTOBER 11, 2023
Applies to:
Acme Packet 6350 - Version S-Cz8.3.0 and laterInformation in this document applies to any platform.
Goal
While running a HW Diagnosis on a new SBC 6350 we´ve just received, it failed because of the testBoomer0Oct1DdrRandomXor.
Can you tell us how to proceed?
testBoomer0Oct1DdrRandomXor---------------------------------------------->23%
Error: Diag dump of cav temp sensor:
23%
Boomer 0: LM83-1 Port 4: Cavium 1 Chip Temp : T= 51 C
FAILED
[DiagLog Start]
[ERROR]: PID:7405 (1) Function:DiagOctRunTests
09:55:55 AM on 12/21/20 TEMP: 21 C
DiagOctRunTests(): core6 shows an error count of 5
[ERROR]: PID:7405 (2) Function:DiagOctRunTests
09:55:55 AM on 12/21/20 TEMP: 21 C
DiagOctRunTests(): ERROR!
Octeon core #6 reports test error.